SONOREX DIGITEC

The new generation
-
Full convenience in use and display for all bath types
-
Easy to operate - self-explanatory symbols well recognizable parameters,
-
Target as well as actual values - brightly lighting LED-display
-
4-step-operation as "plug and clean"
-
Adjustable temperature range: 20-80 °C, with LED-display for target value and actual value of temperature
-
Optical signal in case of excess temperature
-
Timer for countdown and continuous operation
-
DEGAS: adjustable pulse sound level for removing unwanted air bubbles, visible at LCD-display
-
Automatic short-time ultrasound during heating
-
Up period to avoid delay in boiling - switch-off possible
-
Medical device class I
-
Quality management system according to the requirements of EN ISO 13485
-
Protection class IP 33 at highest possible level through liquid-tight mains cable and housing front without openings.
-
SweepTec for permanent sound field oscillation ensures even and gentle cleaning
-
Automatical safety shut-down 12 hours after last keypress
-
Marking of filling level for safe dosage
-
One-piece welded drain bow
-
Transducers with high efficiency
Light & Radiation Systems
Agriculture Technology & Scientific Instruments Distributor
Refrigerated Bath

Applications
Today, ultrasound is an integral part in both pathology and analysis laboratories where rapid diagnosis and a high degree of process effectiveness are required. The new SONOCOOL from BANDELIN now combines the process accelerating effect of ultrasound and simultaneous cooling of the sample.
During the histological analysis of samples, in oncology, for example, bone decalcification is an important step as only decalcified samples can be suitably prepared for later analysis without contamination. The tedious process used so far can now be accelerated considerably using ultrasound. The morphological structure of the sample, however, is preserved by the integrated cooling. A substandard sample, the diagnosis of which would be difficult or impossible, is avoided. The results are available in a shorter time.
Using SONOCOOL, the catalytic effect of ultrasound can now be used on heat sensitive samples in analysis laboratories. The cooling function means that exothermic reactions can be controlled and the processes carried out faster and effectively.
Flyer SONOCOOL
The ultrasonic unit SONOCOOL 255
-
compact design
-
increased life span by welded tank: stainless steel AISI 316Ti, 2 mm thick
-
lid made of glass allowing easy cleaning and sample observation
-
Level sensor for liquid control as dry run protection
-
lighted LCD display for remaining time – actual temperature – pause/diagnostics – set time/set temperature – ultrasonic power
-
serial interface for remote control (PC)